Orion ISS KEYPAD S2000-K User’s Manual
This User’s Manual is intended to help for studying operability principles and maintenance of the S2000-K Keypad of versions 1.04 and above. Please read the instructions completely before connecting, operating, adjusting, or maintaining this product. The following terms are used throughout the Manual: Alarm Loop (or Loop, or LP): The electrical circuit with non-addressable fire or intrusion detectors (or other non-addressable devices) included.
S2000-К Table of Contents Features and Design.............................................................................................................. 5 Specifications ........................................................................................................................ 9 Operating.............................................................................................................................. 11 Indication .................................................................
Orion ISS www.bolid.
S2000-К Features and Design FEATURES AND DESIGN 5 www.bolid.
Orion ISS The S2000-K keypad is designed to operate as the part of an Orion Integrated Security System (ISS) which enables users to be authenticated via their PIN codes / access devices and to input authorized commands to control various functions of the security system, including: Ø Observing current statuses of specified system partitions Ø Arming specified system partitions Ø Disarming specified system partitions Ø Limited access into protected premises The S2000-К keypad is connected to a syste
S2000-К Features and Design sign does not provide usage in presence of aggressive media, dust, and also in fire-hazardous spaces. The S2000-К keypad is equipped with the green backlit liquid crystal display (LCD), 1 x 16 characters (2). In the quiescent mode the display indicates current time.
Orion ISS www.bolid.
S2000-К Specifications SPECIFICATIONS Ø 16 backlit buttons Ø 16-character backlit LCD Ø Non-volatile event log for storing last 255 received events Ø Light and Sound Alarm Indication Ø Non-volatile event log for storing last 16 keypad events Ø Input Voltage 10.2 ÷ 28.4 VDC Ø Consumed Current 50 mA @ 12 VDC or 25 mA @ 24 VDC Ø Operating Temperatures +1 °С to +40 °С Ø Overall Dimensions 146 ´ 105 ´ 35 mm Ø Enclosure Material Plastic 9 www.bolid.
Orion ISS www.bolid.
S2000-К Operating OPERATING 11 www.bolid.
Orion ISS INDICATION S2000-К indication is realized by means of the LCD, the LED indicator, and the audible sounder (beeper). The S2000-К LCD can work either in the quiescent mode (also called the Time Display mode), or in the Command Input mode when the dialog between a user and the system is carried out, or in the Event Display mode when the S2000-K displays system messages received from the network controller (if the last option is set).
S2000-К Operating ACCESS REQUESTS When the S2000-К keypad is used in an access control system, to request access into protected premises it is necessary to enter four-digit password (PIN code) which must be registered by the network controller with appropriate privileges.
Orion ISS Request with the Rights to Access through Several Doors ENTER CODE: Switch the S2000-К, if necessary, into the Time Display mode (see above) and type your four-digit password on the S2000-K keypad (or present your electronic access device to a reader which is assigned to this S2000-K). vDOOR:ХХХХ If the entered password (presented access device) is registered in the system and has the relevant access rights, the number of one of the doors accessible to the user will be represented on the LCD.
S2000-К Operating ARMING AND DISARMING If the S2000-К keypad is used in a fire and intruder alarm Orion system for authorized arming and/or disarming specific system partitions, to execute a required operation it is necessary to enter four-digit user password (PIN code) from the keypad or present the appropriate electronic access device to a reader which is assigned to this S2000-K keypad.
Orion ISS Arming and disarming are executed when the S2000-K is in the current time display mode, which can be reached, if necessary, by pressing the CLEAR button. Examples of arming/disarming procedures using the S2000-K keypad are given below. Partition Arming Procedure ENTER CODE: Switch the S2000-К, if necessary, into the current time display mode (see above).
S2000-К Operating Using the t and u buttons, it is possible to review if there are other non-armed zones in the partition. To return the display back to indicate the partition status and to proceed to the other partitions press CLEAR or ENTER. Partition Disarming Procedure ENTER CODE: Switch the S2000-К if necessary into the Time Display mode. If the presented authenticator is intended not only to arm/disarm but also to gain access, press the ON button to switch the display to the Command Input mode.
Orion ISS REVIEWING SYSTEM EVENTS AND PROCESSING ALARMS The Event Display mode and the Indicate Alarms mode (for the messages received from the network controller) are optional and should be set specially while configuring the system (see the Section Programming the S2000-K to Display Events and Indicate Alarms of this Manual).
S2000-К Operating To confirm receiving of an alarm message, press the ENTER button. After that the alarm is considered to be accepted, the LED indicator turns off, and the display switches into the Time Display mode. The alarm message also can be dropped from the display using the CLEAR button. In the last case display also switches into the Time Display mode, but message reception is considered to be not confirmed, and the LED indicator continues to work in blinking mode.
Orion ISS KEYPAD OPERATIONS SUMMARY Requesting Access Switch the S2000-K display to the Time Display mode (if necessary) CLEAR Type your password (or present your access device) s Select the proper door from the list of available ones t or u, or a door # Request access via the selected door ENTER Arming/Disarming Switch the S2000-K to the Time Display mode (if necessary) CLEAR Turn arming / disarming on (if necessary) ON Type your password (or present your access device) Review statuses of availa
S2000-К Operating TRANSMITTING S2000-K EVENTS TO THE NETWORK CONTROLLER The S2000-K keypad automatically transmits the network controller which this one is connected to the messages about its current status such as: DEVICE RESET TAMPER ALARM The device enclosure has been open TAMPER RESTORED The device enclosure has been closed The keypad provides buffering of events that should be transmitted to the network controller via RS485 interface in case of communication loss.
Orion ISS www.bolid.
S2000-К Installation INSTALLATION 23 www.bolid.
Orion ISS There are no potential hazard electrical circuits within the S2000-К. Do SHUT OFF the keypad power before wiring and maintaining the S2000-K MOUNTING 95 105 65 4 holes Æ 4 35 146 Figure 1. S2000-K Overall and Mounting Dimensions The S2000-K is to be mounted on walls or other constructions within the premises which are protected against atmospheric fallouts, mechanical damage, and unauthorized access. Select the mounting location that is to be approximately 1.5 m above the floor.
S2000-К Installation WIRING Mount and wire the S2000-К as shown in Figure 2. Wires are connected to the S2000-K by means of the screw terminal blocks. S2000-К Power Supply 0V +U XT1.1 1 0V 2 +U XT1.2 A 3 B 4 To a Network Controller (Orion PC or S2000(М)) RS-485 Figure 2. S2000-K Wiring Diagram Connecting the Orion RS-485 Interface Bus To connect the S2000-K to the network controller via the RS-485 interface bus connect A and B terminals of the ХТ1.
Orion ISS GETTING STARTED After mounting and wiring the S2000-K, turn its power on. The keypad LCD shall backlight, the keypad sounder shall respond with a beep. The S2000-K being communicated with the network controller over the RS-485 interface, the keypad LCD shall display the current time. Otherwise, the keypad LCD shall display NO RS485 LINE, the keypad LED flashing once per a second.
S2000-К Programming PROGRAMMING 27 www.bolid.
Orion ISS After installing the S2000-K, set keypad configuration parameters and modify the network controller database in order to use the S2000-K as a part of the Orion system. To program the S2000-K connect it to a personal computer via one of the Bolid manufactured interface converters such as S2000-PI, PI-GR, S2000(M) in the Converter Mode, S2000-USB, USBRS485, etc.. Install the Orion Device Configuration Tool, the UProg, on the computer.
S2000-К Programming To reach the S2000-K settings you can also read the keypad configuration from a data storage device using the File ® Load Configuration File command (or the button on the PC keyboard, or the tool). Moreover, you can create a new configuration file for the S2000-К by means of the File ® New Configuration command (or buttons on the PC keyboard, or the tool from the Toolbar).
Orion ISS The specified address of the S2000-К can be unset to its factory value (127). To do this, remove the keypad top cover and press the tamper switch by long-long-long-short pressing. Here the “long” means “for more than 1 s” while the “short” means “for no more than half of a second”. The pauses between pressings shall not exceed half a second each.
S2000-К Programming NETWORK CONTROLLER SETTINGS The network controller can be programmed either by means of the PProg Console Configuration Tool (if an S2000/S2000M/S2000/L is used as the network controller) or with the help of the Orion Database Administrator Software (if the system operates under an Orion Software). Full description of the network controller programming process can be found in the Manual for the network controller being in use.
Orion ISS Figure 4 Also, you can add the S2000-K descriptor to the console database by means of the tool from the Devices window toolbar, defining all the keypad parameters manually.
S2000-К Programming control command. The procedures of programming user rights are common and out of the scope of this Manual. If the S2000-K is used for authorized access requests, each user should be assigned to an access code for passages through the specific doors. An access code can be used both for access control and arming/disarming the S2000-K. Keypad rights are defined by specifying in the controller database the list of partitions which can be managed using the S2000-K.
Orion ISS To assign the S2000-K keypad to the list of partitions provided that users will be authorized via entering their PIN codes directly from the keypad, drag and drop the relevant partition descriptors from the bottom window on the keypad descriptor in the Device Rights window as shown in Figure 5. To control partitions by the combined way of authorization/control, firstly assign the controlled partition (partitions) to a device whose reader will be used for user authentication.
S2000-К Programming For the PProg, use the following procedure. 1. Select the Partitions tab by pressing on the Page Icon Toolbar, or browsing pages by arrow buttons on the Quick Access Toolbar, or activating the Pages®Partitions®Partitions menu com(see Figure 7). mand. Add a new partition descriptor by clicking Figure 7 Then, in the bottom window select a group of the zones which will be included to the new partition and drag and drop them on the partition descriptor (see Figure 8 and Figure 9).
Orion ISS Figure 8 Figure 9 www.bolid.
S2000-К Programming 2. Specify the keypad as the device the events in the selected partitions will be translated to. For doing so, go to the Event Translation tab by pressing , or browsing arrow buttons on the Quick Access Toolbar, or selecting the Pages®Others®Event Translation menu command. Drag the keypad descriptor in the Devices window and drop them on the device tree in the Event Translation window (see Figure 10). Figure 10 37 www.bolid.
Orion ISS 3. The keypad descriptor being selected in the Event Translation window, define in the Inspector window the kinds of events which are supposed to be displayed by the keypad (see Figure 11). Figure 11 www.bolid.
S2000-К Programming 4. Switch the bottom window of the page to the partition display mode by clicking (see Figure 12) or selecting the relevant menu command. The list of system partitions will appear in the bottom window. Figure 12 39 www.bolid.
Orion ISS 5. Drag and drop the partitions which events will be displayed by the keypad from the Partitions window on the keypad descriptor in the Event Translation window (see Figure 13). Figure 13 6. Now configuring is completed. www.bolid.
S2000-К Maintenance MAINTENANCE 41 www.bolid.
Orion ISS TROUBLESHOOTING s After the S2000-K is turned on, its display shows nothing Make sure that power is applied to the power terminals of the S2000-К s S2000-K displays ‘NO RS485 LINE’, with LED flashing once per second Check whether the keypad is properly connected to the network controller via the RS-485 interface s s Make sure the А and В wires of the RS-485 bus are properly connected to the А and В keypad terminal block.
S2000-К Maintenance INSPECTION Once per a year personnel of the Service Company shall perform a scheduled inspection of the S2000-K in order to check its operation condition and find out potential defects. If during the warranty period the keypad does not meet any requirements set forth in this section, this will be the grounds to raise a climb to the manufacturer.
Orion ISS S2000-K Testing Procedure For testing operability of the S2000-K, wire the keypad as shown in Figure 14. Two resistors of 220 Ω and 0.125 W, R1 and R2, shall be brought between the S2000/S2000M console and the S2000-K keypad as shown in the diagram in order to introduce damping into the communication line between the devices. The keypad pre-operation time doesn’t exceed three seconds. 1.
S2000-К Appendix System Events Displayed by the Keypad LCD 9 www.bolid.
Orion ISS Partition Armed ARM 7 U 80 The partition #7 has just been armed in response to presenting user authenticator #80 Partition Disarmed DARM 7 U 11 The partition #7 has just been disarmed in response to presenting user authenticator #11 Loop Armed ARM Loop Disarmed DARM Arming Failed FARM 7 018/003 Arming the loop #3 connected to the device #18 and included to the partition #7 has failed Zone Disconnected ZTD 2 007/001 An addressable device which belongs to the partition #2 has been
S2000-К D007 A user has presented to a reader of the device with the network address 7 the authenticator #80 registered by the network controller ECOD 405(l) D001 A user has presented to a reader of the device with the network address #1 the authenticator #405 registered by the device itself Device Tamper Alarm TA D001 The enclosure of the device with the network address 1 has been open Device Tamper Restored TR D001 The enclosure of the device with the network address 1 has been closed Device
BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidiaries («Seller»), 4 Pionerskaya Str., Korolev 141070, Moscow Region, Russia warrants its security equipment (the «product») to be free from defects in materials and workmanship for one year from date of original purchase, under normal use and service.
4 Pionerskaya Str., Korolev 141070, Moscow Region, Russia Phone/fax: +7 495 775-71-55 Email: info@bolid.ru, overseas@bolid.com www.bolid.