User`s manual

Orion ISS
www.bolid.com 80
ACCESS KEY CONFIGURATION PARAMETERS
Up to 4096 key descriptors (8192 for the S2000-2 rev.01) can be stored in the controller database.
The keys can be Dallas iButtons, Proximity cards, PIN-codes and so on. Each key is described by a
set of parameters which is shown in Table 10.
Table 10. Key Configuration Parameters
Parameter Name Function Description Range
Key Type
Defines functions of the key
User
Master
Unlocking
Locking
Key Is Locked
This attribute provides temporary blocking the key On/Off
Without
Additional Code
No additional code is necessary to identify the key while
the Two Factor Authentication mode is set for a reader
which the key is presented to (see Two Factor Authenti-
cation Section of this Manual)
On/Off
Access Group
A number of an access group which defines common
access rights and limitations which are applied to this
key and are common for all keys assigned to this access
group
0…32
Validity Limitation
Defines key activity limitations depending on date On/Off
Validity Period
Defines the period of dates when the key is active
01.01.2000 …
… 31.12.2255
The Key Type parameter defines the destination of the key.
User keys are intended to access or to arm/disarm loops.
Master keys are intended to switch the controller into the programming mode for hardware program-
ming (adding) new keys. All keys programmed by hardware with the help of a Master key will be of
User type.
Unlocking key is intended to open access (to implement free pass mode) and restore the Controlled
Access mode (see Access Modes Section) and also to arm/disarm alarm loops.
A Locking key is intended to lock access and restore the Controlled Access mode (see Access Modes
Section) and can be also used to arm/disarm loops.
The Key is locked switch setting prohibits operation for a key of any type. It is used to lock a key
temporary (e.g. if the key is lost) with possibility of its subsequent recovery.
The Without Additional Code parameter is intended to simplify identification of several keys if the
Two Factor Authentication mode is used for other keys (see Two Factor Authentication Section of this
Manual). If the Two Factor Authentication mode is not used (neither at entry, nor at exit) this key pa-
rameter is ignored.