Specifications
Signal Tones:
• Contact closure input controlled tone annunciation
• Tone signaling can be directed into a specific group of zones
• Tone can be selected as tone burst, chime, or 4 quick beeps
• Tone can be selected to follow state of contact closure
input or preset burst length
Time Tones*:
• Built-in real-time clock
• Controls up to 8 time-triggered tone-signaled events
• Each time-triggered event’s tone can be
directed to a specific group of zones
• Time-triggered tone burst length adjustable
(2-8 seconds) or chime tone
• Simple programming of times and events through the telephone
• Master clock synchronization ability
Two-Way Communications*:
• Provides hands-free, 2-way talk back communications in 70V
paging systems (amplifier required)
• Zones can be individually selected to be talk back or one-way only
• “Privacy Beep” can be enabled in talk back zones to prevent
eavesdropping
* Requires PCMTBM Module
Power Audio Power Operating
Model Requirements Capability
+
Current
Dimensions
PCM2000
12V DC@1.5A Power Supply
250W 1.5A max.
1-1/2" W x 7-1/2" H
(not included –
(9-zone system) (9-zone system)
x 4-1/4" D,
PCMPS2 recommended) each module
Product
Weight
1 lb.,
each
module
+
Separate Amplifier Required
Accessories
RPK84
Rack Mount
Kit
RPK88
Rack Mount Kit
PCMPS2
Power Supply
(12V DC)
www.bogen.com
35
PAGING CONTROL
Technical Specifications for PCM2000:
The RPK88 Rack Mount Kit is
designed to flush mount the
modules of a PCM system.
The rack will hold up to ten
modules in two assemblies.
It allows for easy mounting of these
modules in a standard 19" audio rack
(the RPK88 is six rack spaces high).
The kit includes twelve wiring
saddles,
numerous knockouts for wire access, eight
mounting brackets, and eight #6 x 1/4” screws.
(Rack screws not included.)
PCMTIM
Telephone Interface Module
A universal interface connects
to any type of telephone port,
rapidly and trouble-free.
Provides input for night
ringer and emergency page
override. One required per
system.
PCMCPU
Central Processor Module
The PCMCPU controls system
operation and holds all pro-
grammed parameters. One
required for every 3 PCMZP
M
modules (9 paging zones).
PCMZPM
3-Zone Module
The 3-Zone module provides
3 paging zone outputs.
Increasing system capacity is
as easy as adding an addi-
tional module, up to 3 zones
at a time. The zone outputs
can drive 70V or self-amplified
speaker systems. Relay driver
outputs mirror the state of
each paging zone to control
external equipment. If desired,
the system-wide background
music can be disconnected and
a separate music
source can
be connected to any PCMZPM
module. Background music
can also be inhibited in any
zone.
PCMTBM
Talk Back Module (optional)
Allows 2-way, hands-free
talk back communications
throughout the paging sys-
tem. The built-in real-time
clock allows up to 8 user-
scheduled time tones to be
emitted in a specific group of
zones. The clock can be
synchronized with an external
master clock. Only one
PCMTBM is required for the
entire system, when needed.
PCM2000 Modules: