Manual
5
Jumper Selections, cont.
Relay Priority Level
The relay setting determines what priority level and above will cause the relay to energize. Since
this module’s relay must receive a mute signal from a higher priority module to change states, it is
only possible to use the three lower priority levels (2, 3, 4). Priority Level 1 (highest) is not
applicable.
Output Gating
The output signal can be available continuously or available only when the relay priority level set-
ting has been met or exceeded. When set to ACTIVE, it provides continuous signal output. When
set to GATE, it provides output based on priority level.
Relay Contacts
This module’s screw terminal relay contacts can be set for normally open (N.O.) or normally
closed (N.C.) operation.
Output Bus Assignment
The output signal can be taken from the module’s A bus, B bus, or the unit’s MIX bus. On some
Bogen amplifier products, the A and B buses may be tied together.