Data Sheet
The PCM Zone Paging System shall supply the following features
and functions:
1. Simultaneous high-power and low-power paging. Total system
high-power audio capacity of 250W.
2. A minimum of three paging zones and maximum zone
capacity of ninety-nine (99) paging zones. The system shall
be expandable in groups of three zones.
3. Up to 32 field-programmable paging zone groups, each con-
sisting of 1 to 99 zones.
4. Field-programmable Night Ringer Zone Group, consisting of
from 1 to 99 zones. This feature shall be activated by high-
voltage ring signal or contact closure.
5. Field-programmable Emergency/Shift Change Zone Group,
consisting of from 1 to 99 zones. This feature shall require
activation by a customer-supplied contact closure, and sound
a user-selected tone. The user shall have the choice of no
tone (allowing use of outside tone source), tone burst (1-7
sec. duration, user-selected), single chime, or quad beep.
6. Emergency All-Facility Page Override. This feature shall be
activated through a loop start trunk or through contact clo-
sure and dry audio input. It shall override the normal paging
features of the system, sound a user-defeatable alert tone
in all zones, and open an audio channel for a voice page.
7. Built-in, talkback amplification of central-amplified zones.
This feature shall require the addition of the PCMTBM
module.
8. Background music assigned per zone and local background
music sourcing capability.
9. Field programmable Code Call Zone Group, consisting of
from 1 to 99 zones. The user shall have the choice of
pattern or echo code calls, and repeat functions.
10. Eight daily time-triggered signaling events. This feature
requires the use of the PCMTBM module.
11. Two (2) C-form relay contact sets for activating external
equipment. The contacts shall change state when the unit is
activated.
12. Capability of providing uninterrupted background music to
all zones not being paged.
13. Non-volatile RAM shall be included to allow for retention of
programming information during power interruptions
14. Screwdriver-adjustable volume control of confirmation,
pre-announce, error, and shift change/emergency-call tones.
50 Spring Street, Ramsey, NJ 07446 USA
Tel.: 201-934-8500 • Fax: 201-934-9832
www.bogen.com
Architect & Engineer Specifications, cont.
RPK84
Rack Mount Kit
• Holds up to 6 Modules
in one assembly
• Fits in a standard rack,
4 rack spaces high
RPK88
Rack Mount Kit
• Flush mounts up to
10 Modules in two
assemblies
• Fits in a standard rack,
6 rack spaces high
• Includes wiring saddles
and knockouts for wire
management
Mounting Accessories