Installation Manual
The combined total power of each speaker tap must not
exceed 80% of the rated amplier power in either Bridged
70V/25V/8Ω mode or 2CH 25V/8/4Ω mode.
Failure to observe minimum speaker impedance will cause
the amplier to self protect until the speaker conguration
is corrected.
6. If using Line Input, route the input.
The amplier uses a balanced line level (up to 2V RMS) ana-
log audio input. You can use either XLR or Phoenix (but not
both) as the input.
This input can be routed to either or both amplier channels,
depending on the setting of the Amplier Mode switch.
7. Plug the power line cord into the power source.
8. Toggle the Power switch to the On position.
9. For information about conguring the amplier for the
Nyquist system, refer to the Nyquist Audio Power Ampliers
Conguration Manual.
Power Ratings
The NQ-A2060 can provide 60 Watts into two separate chan-
nels into 25V, 8Ω, or 4Ω, or 120 Watts Bridged (one channel) into
70V, 25V, or 8Ω load congurations.
The NQ-A2120 can provide 120 Watts into two separate chan-
nels into 25V, 8Ω, or 4Ω, or 240 Watts Bridged (one channel) into
70V, 25V, or 8Ω load congurations.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
8