Installation Manual
NQ-A2060-G2 and NQ-A2120-G2
Viewing and Understanding LEDs
Two LEDs appear on the front of the amplier. One is labeled POWER
and appears as solid red during initial power up, ashes green during
a boot sequence, and appears solid green when fully booted.
The STATUS LED uses the following
indicators to provide information
about the appliance:
• FLASHING RED –
No network connection found.
• SOLID BLUE – The amplier is
in an uninitialized state and is
not associated to a server.
(The server may be in a
discovery mode.)
• SOLID GREEN – The amplier is registered to a Nyquist server and is in
normal operation.
• FLASHING GREEN – The amplier has an IP address but
is not registered with the Nyquist server.
• SOLID RED – The amplier needs to be rebooted or reset
so that the Nyquist application can resume.
• FLASHING BLUE – The amplier is updating.
+ –
G
+ –
G
LINE INPUT 1
LINE INPUT 2
Clipping, Protection, and Temperature Indicators
In addition to the LEDs that appear on the actual appliance, separate
amplier module signal clipping, protection mode, and temperature
status indicators appear in the Nyquist amplier’s web-based user
interface.
For more information about these status indicators, refer to the
Nyquist Audio Power Ampliers Conguration Manual.