Details for Connecting Two SC-2030 Controllers with TM-2030

UP
DOWN
TM-2030
Connected
Overcurrent if flashing
System volts:12V-down. 24V-up.
SOLAR
BATTERY
Unit 1
SC-2030
Solar
Charger
For 12V or
24V systems
only
G2
G1
B1
B2
SIG
Back of
TriMetric TM-2030
battery monitor
Set 2 of solar
panels. Solar
current shown
on TM-2030
“So2” display.
Set 1 of solar
panels. Solar
current shown on
TM-2030 “SoL”
display.
Temperature also
displayed.
To Battery
Bank
shunt
Temp
sensor
Male end
not used.
Connect
temperature
sensor to
Unit 1.
4 (or 5) wires to shunt and battery.
3 plug phone
adapter. 3
female
connections
CROSSED
communication
phone cable
NON CROSSED
communication phone cables
Wiring for two
SC-2030 with
one TM-2030
Each SC-2030 can deliver up to 31 Amps to batteries. If current exceeds 31
amps, this will not damage the SC-2030 but the battery current will then be
limited to less than 31A to protect the charger and the yellow light will flash.
One unit must be distinguished by inserting a “unit 2” identifying jumper on
connector J6 on rear of SC-2030. Temperature sensor should be placed
on unit 1.
Battery Type: AGM -down. FLOOD -up
UP
DOWN
TM-2030
Connected
Overcurrent if flashing
System volts:12V-down. 24V-up.
SOLAR
BATTERY
Battery Type: AGM -down. FLOOD -up
Unit 2
SC-2030
Solar
Charger(2)
For 12V or
24V
systems
only