Bogart Engineering SC-2030 Technical Manual
G2
G1
B1
B2
SIG
12 TO 48V
BATTERY
SYSTEM
(This can be several
batteries connected
together to make one
system)
UP
DOWN
Battery Type: FLOOD-up.AGM-down.
TM-2030
Connected.
Overcurrent .
System volts:12V-down. 24V-up.
SOLAR
BATTERY
SC-2030
Solar
Charger
For 12V or
24V systems
only
Back of
TriMetric TM-2030
battery monitor
To All other
loads and
charging
sources.
To chassis
ground if used.
+
+
+
For SC-2030 charger: solar panels
should be ā12Vā type for 12V battery
systems. Up to 30 amps of panels
can be used. If more than 30 amps is
used the SC-2030 will safely limit
current.
1 A FUSE
Optional battery
temperature sensor.
Small wires go to
connector in SC-2030
SHUNT
Choose 500A/50 mV or 100A/100mV
TWO KELVIN
SCREWS
4 small wires from battery
to meter up to 100 feet.
Usually a cable with four
#22 or #24 wires is used.
Optional connection for
measuring voltage only of
second battery system,
such as starting battery.
For SC-2030 Solar Charger
Communication cable: Commonly
available 4 wire RJ-14 telephone
cable plugs into SC-2030 and TM-
2030. Can be more than 100 ft.
Green items for SC-2030
Solar Charger only.