TM-2030 Technical Manual
AMPS
Hold SELECT 3
seconds to view
VOLTS
% FULL
B2
B1
when flashing-meets "CHARGED" criteria
AMP-HOURS FROM "FULL"............RESET: to 0 Amp-hours
DAYS SINCE "CHARGED"................RESET: to 0 days
DAYS SINCE EQUALIZED................RESET: to 0 days
REPLACED PERCENTAGE FROM LAST DISCHARGE
=AMPS or =WATTS
SELECT
RESET
Operating and programming instructions at
www.bogartengineering.com/ins
TM 2030-RV
Bogart Engineering
CHARGING
BATTERY
REMINDERS
=TIME TO CHARGE
=TIME TO EQUALIZE
=BATT. VOLTS LOW
AH = Amp-hours discharged from a full battery.
dSC= Number of days since the batteries have been fully charged
AP Pr
AP Pr P4
or = Shows amps or watts entering/leaving the batteries
Amps : “ ” or Watts: “ ” (Which one? see table 2, page 7.)
rPC Shows how much energy you’ve replaced of the last discharge
See Section 2.1 for more details on these 5 items.
dSE= days since the batteries have been equalized (if used)Number of
IMPORTANT DISPLAY NOTE:
Flashing decimal point means “multiply
the number seen by 1000”
When shows “battery 1 is charging”
(“amps” or “watts” is positive)
lamp means battery is charged.
lighted
Flashing
Lamp flashes and display occasionally shows letters
when:
battery should be recharged “Ch.F”
or “battery should be equalized” “Ch.E”
or “battery voltage low” “b.LO”
these
See section 2.2 for details
TM-2030 Operation Summary
Push quickly to make display toggle through:“SELECT”
Push and hold for 3 seconds until " " pops into
display. Immediately release " ". You will see:
“SELECT” AH
SELECT
AMPS (or WATTS) entering(+) or leaving(-) battery B1
%FULL (for battery 1)
Battery B1 must be
charged fully at least once before this will display.
VOLTS (first battery B2, then battery B1)
The button will reset any of the following:
“Batt% full” (to 100%)
Amp Hours from full (to 0 Ahr)
Days since charged (to 0 days)
Days since equalized (to 0 days)
To RESET any of these:
(1) Use SELECT to view it on display.
(2) Push and hold RESET for 5
seconds.
Except
RESET
when viewing rPC: hold down to
“previous discharge minimum Amp-hours".
RESET view
DO YOU PREFER “AMPS” OR “WATTS” to
show in primary display?
See Table 2, Program P4, to change
TO ACCESS PROGRAM OR HISTORY DATA
NOT SURE WHERE YOU ARE?
:
Hold down and watch for “ ” (Program) or
“ ”(History) at left in display, then release
. See sections 5 and 6.4 for details on
data. See sections 4 and 6.3 on
data.
Push SELECT
repeatedly until you get back home.
SELECT P1
H1.1
SELECT
program history
TO ACCESS PRIMARY (MOST OFTEN USED) DISPLAYS
BATTERY REMINDERS: (optional)
CHARGING LIGHT:
TO ACCESS SECONDARY (LESS OFTEN USED) DISPLAYS
3
Shows view of TM-2030-RV, but
TM-2030-A operation is identical.
Push " " quickly to toggle through:SELECT
FIGURE 1