Bogart Engineering SC-2030 Technical Manual

Bogart Engineering
16 of 16
TABLE 4: Programmed values for each P22 charging profile number. See *NOTE below
All values are normalized to a “capacity” of 220Ahr. After placing a profile in P22, then change the P3
setting to your value unless your system has capacity=220 Amp hr.
Battery type
( with total system volts not battery volts)
Profile
number
P22
P1
Absorb
V
P2
Amps
setpt
P3
capacity
Ahr
P14
Time
hr
P15
high
V
P16
float
V
P20
Over
charge
P21
Finish
amps
"Generic" wet cell (12V)
1
14.4V
2.0%
220AH
4.0h
15.7
13.2
10%
3.0%
"Generic" wet cell (24V)
2
28.8
2.0%
220AH
4.0h
31.4
26.4
10%
3.0%
Trojan wet cell (12V)
3
14.4V
2.0%
220AH
4.0h
16.2V
13.4
10%
3.0%
Trojan wet cell(24V)
4
28.8V
2.0%
220AH
4.0h
32.4V
26.8
10%
3.0%
Crown wet cell(12V)
5
14.5V
2.0%
220AH
4.0h
15.9
13.5
10%
3.5%
Crown wet cell(24V)
6
29.0 V
2.0%
220AH
4.0h
31.8
27.0
10%
3.5%
US Battery(12V)
7
14.8V
2.0%
220AH
4.0h
15.5
13.0
15%
3.5%
US Battery(24V)
8
29.6 V
2.0%
220AH
4.0h
31.0
26.0
15%
3.5%
Concorde AGM(12V)
9
14.3 V
2.0%
220AH
4.0h
16.5
13.3
7%
2.0%
Concorde AGM(24V)
10
28.6 V
2.0%
220AH
4.0h
33.0
26.6
7%
2.0%
Deka monobloc(12V) 8A, 8G
11
14.2 V
2.0%
220AH
8.0h
14.2
13.5
20%
5.0%
Deka monobloc (24V) 8A, 8G
12
28.4 V
2.0%
220AH
8.0h
28.4
27.0
20%
5.0%
Interstate(12V) wet cell
13
14.5 V
2.0%
220AH
4.0h
15.3
13.4
15%
4.0%
Interstate(24V) wet cell
14
29.0 V
2.0%
220AH
4.0h
30.6
26.8
15%
4.0%
GNB-Absolyte(12V) VRLA
15
14.3 V
1.0%
220AH
8.0h
14.3
13.5
7%
2.0%
GNB-Absolyte(24V) VRLA
16
28.6 V
1.0%
220AH
8.0h
28.6
27.0
7%
2.0%
Generic-Wet Cell-no hi volt finish
17
14.7
2.0%
220AH
0.1h
15.0
13.2
12%
0FF
Generic-AGM-no hi volt finish
18
14.3
2.0%
220AH
0.1h
15.0
13.3
7%
0FF
*NOTE: We occasionally update these profiles with what we consider better data, so your unit may not have
precisely what’s shown. Manufacturers sometimes change their recommendations. And not infrequently some
battery companies will have slightly different recommendations on the same web site, depending on which page
you look. After loading a profile you may want to check and change any individual program value shown on this
table.
Bogart Engineering
www.bogartengineering.com