Technical data
89
Notes Notes
90
You can adjust the spot diameter and detection
distance by changing the amount of fibers inserted,
but if you jam the fibers in too far, the tip of the fibers
will become separated from the lens.
Tighten the fiber nut after
setting the fiber and NF-DA06
in place in order to fix them so
that they do not move because
of vibrations, etc.
Use M3 cup-point set screws to
mount NF-DA06 if you want to
use set screws.
Insert fibers into NF-DA01/
-DA02/ -DA03/ -DA04/ -DA05
as far as they will go.
You can adjust the spot diameter and detection
distance by changing the amount of fibers inserted.
Tighten the nut after setting the
fiber and NF-DA07 in place in
order to fix them so that they do
not move because of vibrations,
etc.
To clean NF-DW02, use a soft cloth to wipe away all
liquid on the head and bracket. Be sure to check for
condensation on the detector.
If the fibers on NF-DW02/ -TF01 are too short, the
detector may not receive the correct amounts of light
and may not be able to detect consistently.
Use the bracket designed especially for the
NF-DW02 in order to avoid mistakes such as forget-
ting to attach something. Otherwise, the detector
may not be able to detect consistently.
If you use a PVC bracket on the black mat parts on
the steel case, the device cannot detect mistakes, so
perform a thorough check before using the device.
Be careful not to damage exterior of the fibers when
you cut the protective tubes.
Only set NF-DW02 sensitivity after mounting the
completely dry head to the bracket and attaching the
fibers to the amplifier. Adjusting the fiber connection
or position after adjusting sensitivity changes the
amount of light that enters and causes inconsistent
detection.
If you altered fiber connection or position while clean-
ing the device, make sure to adjust amplifier sensitiv-
ity.
The amount of light may decrease when the device is
used for long periods of time at high temperature and
humidity.
Liquids that are not compatible with NF-DW02 head
material (PFA) may cause air bubbles to flood the
detector. This causes inconsistent detection, or
makes consistent detection take more time. Test the
liquid you are examining before beginning.
Make sure that the NF-DW02 bracket does not have
any scratches, dirt or grime, or deformities when you
clean it.
Water droplets on the detection surface may affect its
detection capability. Avoid using this device in places
where it can come into direct contact with water.
Remember to check for condensation on the outside
of pipes.
Notes about NF-DA06
Notes about NF-DA01/-DA02
/-DA03/-DA04/-DA05
Notes about NF-DA07
Notes about Leak/Fluid Level
/Chemical-Resistant Fibers
c
L
b
a
30
20
10
0
108
Central detection
distance L (mm)
Diameter
= about 0.9
Diameter
= about 0.7
*The numbers inside the graph
are spot diameters (mm)
Distance inserted
nut
nut
a:distance inserted
b:25-a
L:central detection distance
c:spot diameter
M3
cup-point set screw
This part cannot
be tightened.
a
b
L
c
20
10
0 108
Central detection
distance L (mm)
Diameter
= 0.8
Diameter
= 0.6
Diameter
= 0.5
*The numbers inside the graph
are spot diameters (mm)
Distance inserted
a:distance inserted
b:25-a
L:central detection distance
c:spot diameter
AmplifiersFlexible
Various Detecting Scheme
Environment-resistantLiquid
Extension lens
Various Shape for mounting
Notes
Amplifiers
Flexible
Various Detecting Scheme
Environment-resistantLiquid
Extension lens
Various Shape for mounting
Notes
Mounting Chemical-Resistant
Angled-Head Fibers (NF-TY05)
Mounting Chemical-Resistant
Angled-Head Fibers (NF-TY05)
Use M3 screws and tighten
them to torques of 0.3Nm or
smaller.
There are two types of slits that come with these
products (the slit that comes with the NF-TZ01/
-TZ02 is one of them). These slits help detecting tiny
objects and prevent saturation when using the fibers
at close range. However, applying adhesive slits
shortens the detection distance.
Align the pointed end of the adhesive slit to the top of
the fiber and apply it as shown in the diagram below.
Keep the heat-resistant fiber part at least 150mm
from the boundary of the ordinary-temperature zone
as shown below in order to protect amplifiers.
Do not directly expose amplifiers to radiation heat or
hot air.
The metal bracket on the tip of the heat-resistant fiber
(up to 350℃) and stainless steel sheath may change
color when used at high temperatures, but this does
not affect their detection capability.
①
Pull the positioning lever
open, in the direction of the
arrow.
②
Push the moveable part in the
direction of the arrow, loosen
the zip tie, and readjust the
mounting position.
③
Close the positioning lever so
that it will not loosen.
heat resistant side
through beam
or reflective,
free cut fibers
heat-resistant
fiber part
at least 150mm
plug
joint
reflective fiber
How to Adjust Position
Adhesive Slits
(come with products)
How to Apply
Adhesive Slits
positioning lever
positioning lever
loosen
readjust
push
(Note 1) :
(Note 2) :
You must reset the sensitivity after readjusting the mounting position.
The positioning lever is for readjusting the position on this device, not for tightening the zip
ties. Tightening the zip ties while the positioning lever is open and then closing the lever will
damage the fibers.
M3 screws
(not included
with product)
Caution for Heat-Resistant Fibers
Notes about Adhesive Slits
Included With NF-TZ01/-TZ02
/-TZ03/-TZ04
Do not use these products with the chemicals listed
below.
Fused alkali metals (sodium, potassium, lithium, etc.),
fluorine gas (F2), ClF3, OF2 (even in its gaseous state)
and other chemicals that may erode PFA. Hydroflu-
oric acid at high temperatures, nitric acid, chlorine
and other chemicals with high permeability.
Keep the heat-resistant fiber part at least 150mm
from the boundary of the ordinary-temperature zone
as shown below in order to protect amplifiers.
Do not directly expose amplifiers to radiation heat or
hot air.
Notes about NF-TY01(-□)
/-TY02(-□)/-TY03-TF03/-TY04
/-TY05(-□)/-DY01(-□)
NF-TZ03/-TZ04
NF-TZ01/-TZ02
0.5mm
12mm
0.5mm
32mm
12mm
pointed end
heat resistant side ordinary temperature side
ordinary temperature side
at least 150mm