Technical data

85
Notes
86
When mounting fiber bracket
When using bracket
Head-On Type/NF-RB01
The Structure of Vacuum-Resistant Fibers
Mounting
For NF-DN01
Side-On Type/NF-RB02
A Note About NF-RB01/-RB02
Mounting NF-RB01/-RB02
Mounting Vacuum-Resistant Fibers
(NF-TN01/-TF02)
This product’s aperture angle is extremely small, and
there are cases where the fibers do not transmit light
because of the way they were mounted.
As shown in the diagrams below, mount the fiber
heads and reflectors so that their centers align with
one another. Make sure that the optical axis is aligned
properly.
Mount NF-VN02 optical joints to the vacuum
chamber wall.
You must attach the O-ring included with this
product, and make sure that the O-ring is on the
outside of the vacuum chamber.
Mount NF-VN01 fiber bracket to the NF-VN02
optical joint at atomospheric side.
Mount the vacuum fiber nut to NF-VN02 optical
joint at vacuum side.
Drill two holes into the vacuum chamber (or
flange) wall.
Attach fiber bracket to side-on type fibers such that
they do not touch the detectors.
If you use fiber bracket, you can mount fibers without
using M3 set screws.
When mounting with M3 cup-point set screws
Mount the fibers with M3 cup-point set screws within
the mounting ranges shown in the diagram below.
Use cup-point set screws (M3
or smaller) to mount the
bracket.
You can mount the head
without using cup-point set
screws by attaching the
bracket to the steel head.
Detection results may vary between 0 and 20mm
from the detection surface when detecting transpar-
ent objects.
2.6mm
5.3mm
4.75mm
14mm
19mm
3mm
5.3mm
4.75mm
14mm
19mm
Parallel
Parallel
Parallel
Parallel
M3 screws
(not included with product)
4.5mm or greater
M3 cup-point screw
(not included with product)
4mm
(Attachment range)
20mm
(mounting range)
Vacuum-side Atmospheric side
Vacuum-side Atmospheric side
O-ring O-ring
gap
Vacuum-side fibers
Chamber or flange
Optical joints
Atmospheric side fibers
Chamber or flange
5.5 to 6.0mm-diameter
holes
hole
Cup-point set screw
(M3 or smaller)
bracket
(NF-DA51,comes
with the product)
Leak: 1.33x10-10Pam3/s [He] or lower
(Note 1): Make the holes 5.5 to 6.0mm in diameter.
(Note 1): Tighten the nut well.
If the nut is loose, there may be a gap, and the detection distance will drop.
(Note 1): Tighten the nut well.
If the nut is loose, there may be a gap, and the detection distance will drop.
Mount the tip of the vacuum-side fiber.
Mounting
3mm
Use M2 countersunk screws
(not included with this prod-
uct).
The boss insertion holes on
the bottom surface need to
be 1.7mm in diameter and at
least 0.8mm deep.
Screw set screws within 15mm of
the tip of the metal head.
You can mount the heads without
using set screws.
If you use set screws, mount the
heads with M3 cup-point set
screws.
Please take care when mounting this product
because its aperture angle is extremely small, and
there are cases where the fibers do not transmit light
because of the way they were mounted.
As shown in the diagram below, determine a refer-
ence plane, make sure the optical axis is aligned
properly, and mount the receiving and emitting fibers
so that they are parallel to the reference plane.
M2
countersunk screw
(not included
with product)
1.7mm-diameter holes
(greater than 0.8mm deep)
When screwing a tap
into the attachment
5mm 5mm
Tap depth 8mm or more
with M2 x 0.4mm screw
1.6mm-diameter hole
at least 0.6mm deep
Detection
direction
Detection
direction
8mm M2 screws
(included with product)
8mm M2 screws
(included with product)
Boss
Boss
nut/spring washer
/plain washer
1.6mm-diameter hole
at least 0.6mm deep
Mounting plate
thickness less than 4mm
When using the attached
screws and nuts
(Note 1):
The NF-TE01 is pictured above. NF-DE01 is mounted in the same way.
(Note 2): Through beam fibers have the same dimensions. Be aware of the positions of the screw holes
and boss holes when mounting fibers.
NF-TE04/NF-DE04
(Head-On Type)
When not using mounting bracket NF-DA51
(included with this product)
When using mounting bracket NF-DA51
(included with this product)
NF-DC08
NF-TE01/NF-DE01
(Flat-On Type)
NF-TE02/NF-DE02
(Head-On Type)
NF-TE03/NF-DE03
(Flat-On Type)
When screwing a tap
into the attachment
Tap depth 8mm or more
with M2 x 0.4mm screw
1.6mm-diameter hole
at least 0.6mm deep
Detection
direction
Detection
direction
Detection direction
8mm
M2 screws
(included
with product)
8mm
M2 screws
(included
with product)
Boss
Boss
Boss
nut/spring washer
/plain washer
1.6mm-diameter hole
at least 0.6mm deep
Mounting plate
thickness less
than 4mm
When using the attached
screws and nuts
(Note 1): The NF-TE02 is pictured above. NF-DE02
is mounted
in the same way.
(Note 2): Through beam fibers have the same dimensions. Be aware of the positions of the screw holes
and boss holes when mounting fibers.
(Note 1): The NF-TE03 is pictured above. NF-DE03
is mounted
in the same way.
(Note 2): Through beam fibers have the same dimensions. Be aware of the positions of the screw holes
and boss holes when mounting fibers.
(Note 1): The NF-TE04 is pictured above. NF-DE04
is mounted
in the same way.
(Note 2): Through beam fibers have the same dimensions. Be aware of the positions of the screw holes
and boss holes when mounting fibers.
5mm 5mm
7mm
M3 pan head screws
(not included with product)
M3 pan head screws
(not included with product)
2.5mm-diameter hole
at least 1.1mm deep
7mm
Mounting Fibers With Positioning Bosses
Mounting NF-DR09/ -RR01
15mm
Screw tightening range
cap point set screw (M3 or smaller)
cap point set screw (M3 or smaller)
cap point set screw (M3 or smaller)
mounting
bracket
Mounting Through beam Screen Fibers
(NF-TZ01/ -TZ02/ -TZ03/ -TZ04)
Reference plane
Reference
plane
Parallel
Parallel
Optical axis
Good No Good
Notes
Amplifiers
Flexible
Various Detecting Scheme
Environment-resistantLiquid
Extension lens
Various Shape for mounting
Notes
Amplifiers
Flexible
Various Detecting Scheme
Environment-resistantLiquid
Extension lens
Various Shape for mounting
Notes