Table of contents I - INITIAL VERIFICATION . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Unpacking the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 II - INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.1 Single face indoor clock . . . . . . 2.2 Single Face outdoor clock . . . . . 2.3 Double Face clock . . . . . . . . . 2.3.1. Double Face integrated clock 2.3.
ENGLISH I - INITIAL VERIFICATION Thank you for choosing a BODET clock. This product has been carefully designed for your satisfaction based on ISO9001 quality requirements. We advise you to read this manual thoroughly before attempting to manipulate the clock. Keep this booklet during all the life of your clock, so that you can refer to it each time it is necessary. Bodet accepts no responsibility for accidents resulting from any use not conforming with the above provisions.
impulses on a serial ligne ; it is powered by 240 VAC, with a servo second hand. REC MN 1V5 = the clock is a receiver driven by a control unit “Remote keyboard” or radio synchronised control unit “BT radio” that sends minute impulses. RAD DHF = the clock is radio-synchronised by a DHF transmitter and battery supplied. DHF HM 230V = the clock is radio-synchronised by a DHF transmitter; it is supplied in 240VAC. 1.
2.2 Single Face outdoor clock 1 11 2 9 4 8 4 3 7 5 6 5 3 4 2 6 2 1 7 1 9 3 8 12 10 N - Carry out the various connections (external supply : see page 8 and connection to time distribution network : see page 12). 12 L - Hang the clock and fix it with M8 screws (4), without locking it, after you have put the wires (between Ø7 and Ø10) through the waterproof pressure joints (5).
2.3.1. Double Face integrated clock 150 70 Drill the support (wall, pillar, ...) to the required dimensions and fix the bracket. Ø9 - Unscrew by 10 mm the 2 bolts (B) on each face. B - Remove each face by rotating them anticlockwise (for receiver clocks, Do Not forget to disconnect the 2 movements). 6 7 - Fix the double sided bracket after you have put the wires either through the plate support (6), or through the aperture on the side of the bracket (7).
2.3.2 Clock on keyboard 150 70 - Drill the support (wall, pillar, ...) to the required dimensions and then fix the bracket. - If necessary, carry out the various connections (external supply : page 8 and connection to time distribution network : page 12). - Put the wires either through the hinged arm system (6), or through the hole on the side of the bracket (7). - Fix the clock (or clocks) to this keyboard with the 2 threaded shafts (C). 7 Ø9 6 C 2.
III - POWER SUPPLY Installation and maintenance of this equipment must be carried out by qualified personnel only. Electrical installation must comply with current standard CEI 364. (NF C15-100 in France for example). The mains supply for the clocks must include a neutral phase circuit breaker 10A C curb, rapidly accessible. This circuit breaker must be switched off during maintenance operations. Note : the power supply wires must be linked near their fixing point. 3.1.
3.3. AFNOR HM clock low voltage 6/24V Connect the low voltage (TBT) power supply (6 to 24V AC or DC) to the connectors 1 and 2: maximum 1,5 mm2 wire section (5mm bare). It is compulsory, for a correct running, to respect the following parameters. These parameters are calculated considering 8/10 mm wire section with 1A (Microquartz Delta).
3.5. Independent Quartz clock on mains : Single Face. – Connect mains supply (230VAC) to the terminal (20) of the power supply unit (ref.933006). 20 22 – Connect the impulses line between the terminal (22) of the power supply unit and the terminal (2) of the clock. The time base is protected by a 0,2AT / 250V fuse (21). 21 23 Double Face. – Connect mains supply (230VAC) to the terminal (20) of the power supply unit.
3.7. Lighting connection A 10 A fuse or circuit breaker for the lighting power supply should be installed and switched off prior to any maintenance in the clock. N L Lighting 230V + earth N 1 1 2 2 2 L – Connect lighting supply 230V + earth (0,55A) on the terminal (2), the earth wire must be longer than the other ones. – Nota : the power supply wires should be assembled together near their connecting terminal.
IV - OPERATING AND TIME SETTING NOTA : to respect the security rules, the time distribution network must be be SELV-type. - The impulses wires should be assembled together near their connecting terminal. 4.1. Impulses slave clock A time distribution network emits only impulses, so that it is necessary to set the clock at the time of this network. To add a clock on a network, it is necessary to stop this network and to set on time the clock. To set on time the clock, turn the control knob (7 or 8). 4.1.1.
4.1.2. ½ minute and minute serial receiver, - Connect the time distribution network to terminals 1 and 2 on the terminal strip (3). 2 1 3 2 1 3 Impulses 1 To insure the continuation of the serial distribution network, (to avoid to cut the serial line when a slave clock is disconnect) connect the 100 Ohms 1/2 Watt resistor delivered (for 65mA). Leave works 2 minutes. 3 2 - The terminal 3 of the terminal strip (3) is available.
4.2. AFNOR/IRIG-B time signal reception Operating principle of AFNOR HM receiver clock : During 1 hour without reception of the time signal the clock operates with its own time basis. If the signal recovery is achieved within this hour, the clock will be resynchronised automatically. After 1 hour the clock is reset and hands are set on position 12.00. - When switching on power supply, hands are set at 12.00 until the correct reception of the time signal is achieved.
4.3. France Inter radio receiver clock Antenna connection : Connect the 2 wires of the antenna on the FI and GND terminal. Caution: to avoid interferences due to high voltage lighting, the wire between the cable gland and the terminal must be as short as possible. 16 17 15 Check that the dip switch (15) is in France-Inter receiver position, push toward the down of the PCB. When switching on power supply, hands are set at 12.
4.5. Independent Quartz on mains with remote keyboard See the booklet of the remote keyboard, reference : 605198. Attention : in case of a double face clock, check that the Dip switch (6) of the remote keyboard is in “DF” position.
V - TECHNICAL FEATURES Readability : Dimensions : 60m.
France Inter radio receiver clock with synchronous second hand : Permanent power supply : 230V; 70mA. Accuracy : absolute with automatic summer/winter changeover. The electronic of the clock is protected by 2 fuses 2A/250V. Receiver radio DHF : Power supply : 2x 1,5V LR14 batteries. Autonomy : > 3 years. Accuracy of the master clock. DHF 230VAC clock : Power supply : 230VAC 0,2A. Accuracy of the master clock. Independent Quartz on mains with remote keyboard clock : Supply : 230VAC 0,2A.
Supply Operating temperatures Protection index Weight Profil 960 I HM minute // and ½ minute serial receiver -10°C to +50°C IP401 6,5 kg Profil 960E HM minute // and ½ minute serial receiver -25°C to +70°C IP537 15,2 kg Profil 960E HM DFE minute // and ½ minute serial receiver -25°C to +70°C IP437 24 kg Profil 960E HMS minute // and ½ minute serial receiver 230 Volt 50 Hz ±10% -25°C to +70°C IP537 15,2 kg Profil 960E HMS DFE minute // and ½ minute serial receiver 230 Volt 50 Hz ±10% -
VI - WHAT TO DO IF...? What to do if...? 20 ...CHECK. … Check. – The clock (powered by battery) had stopped. – The battery has run out. Replace the battery. Resetting of the time is, automatic for radio synchronised clocks, manual for independent clocks. Dust on the battery contact terminals (+ and -) can disrupt the power supply to the clock. Clean these contact terminals with a soft dry cloth, if necessary. – No synchronisation after the installation.