Specifications

18 VEDEX 3300
For the chimney sweep
Sweeping
Open the combustion chamber door (68).
Pull out the flame trough.
Empty the trough and clean the ash out. Take care to
remove any burnt on ash remains in the trough.
Clean the chamber.
Position the trough in place and close the door.
Fan
The fan is a central part of VEDEX 3300 and should be
treated with care. The fan should be removed and cleaned
about twice a year for optimum function and a long serv-
ice life.
Check that the boiler is off and that no embers are in
the combustion chamber.
Disconnect the fan from the electrical socket on the
boiler.
Remove the long nuts securing the fan to the boiler.
Clean the fan blades carefully to prevent deforming
them.
Reinstall the fan and connect the electrical cable.
Sweeping description
Remove the cover from the mounting points in the
boiler.
Lift out the turbulators from the convection part.
Sweep the convection part.
Reinstall the turbulators.
Reinstall the soot door.