Instruction manual

L4080B
L4006A
FIGURE 8: Honeywell L4006A w/ L8080B
For Models: 50, 120E
FIGURE 6: Beckett or Wayne burner w/ Carlin EZ-Temp
For Models: 32, 33, 40, 50, 51, 71, 120E
FIGURE 7: Honeywell L4103A-1142
For Models: 32, 33, 40, 51, 71E
FIGURE 7 NOTES:
Set point 120°
FIGURE 4 NOTES:
High limit: 190°
Aquastat:
120° set point
15° differential
8
WIRING
F
IGURE 5
: Carlin burner w/ Carlin EZ-Temp
For Models: 32, 33, 40, 50, 51, 71, 120E
(see burner manufacturerʼs instructions for 20e;
6
0200 primary w/ three wire harness)
23420.qxp:23420 Res Oil Water Bro 8/3/11 8:39 AM Page 9