SDS
Report No.: 19PNS120223 07001
GUANGDONG UTL CO., LTD.
Lianding Testing Building, No.18 Center Road of Yayuan Industrial Zone, Nancheng District, Dongguan,
Guangdong, China
Tel: +86-769-3893 3228 E-mail: sales@gdutl.com Web: http://www.gdutl.com
Page 5 of 12
Common Chemical Name
Chemical Formula
Concentration (%)
CAS Number
Cobalt Lithium Manganese
Nickel Oxide
LiNixCoyMn1-x-yO
2
38.0
182442-95-1
Aluminium
Al
5.5
7429-90-5
Graphite
C
24
X
12
21.0
7782-42-5
Carbon Black
C
1.0
1333-86-4
Ethyl Methyl Carbonate
C
4
H
8
O
3
12.0
623-53-0
Copper
Cu
18.5
7440-50-8
Nickel
Ni
1.0
7440-02-0
Lithium Hexafluorophosphate
LiPF
6
3.0
21324-40-3
Note: CAS number is Chemical Abstract Service Registry Number.
N/A=Not apply.
4. FIRST-AID MEASURES
First aid measures
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. If symptoms persist, call a physician.
Skin Contact Remove contaminated clothing and shoes. Wash skin with soap and water. In the case of skin
irritation or allergic reactions see a physician.
Inhalation Move to fresh air. If symptoms persist, call a physician.
Ingestion Do NOT induce vomiting. Drink plenty of water. If symptoms persist, call a physician.
Most important symptoms and effects, both acute and delayed
Swallowing Do not induce vomiting. Get medical attention.
Most Important Symptoms/Effects No information available.
Indication of any immediate medical attention and special treatment needed
Notes to Physician Test symptomatically
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
CO2, dry chemical powder, water spray.
Unsuitable Extinguishing Media: No information available.
Specific Hazards Arising from the Chemical
Formation of toxic gases is possible during heating or case of fire.
In case of fire, the following can be released:
Carbon monoxide (Co)