Installation Sheet

Form No. 8878-69 (Revised 3/10/20) © 2020 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
4
ACA
INLINE
CONNECTOR
-CWB
-HW6
-MJ
-HW6
18 AWG (MIN)
MAX LENGTH 40
2.2a. Optional ACA version: Connect supplied inline
connector and AC adapter.
Do not engage the sensor for 30 seconds after the
connection is made. The sensor will perform automatic
calibration.
2.6. Connect solenoid cable from electronics module to
sensor cable from spout.
2.3. Tighten electronics module assembly to shank and
connect water line(s).
2.2b. Optional HW6 (Hardwired 6V) version: Connect
supplied inline connector and hardwire adapter.
When securing the CWB wires to the screw
terminals on HW6 unit, the BLACK WITH DASHED
MARKINGS should be connected to the Positive
(+) terminal, and the SOLID BLACK wire should be
connected to the Negative (-) terminal.
2.4. Turn on water supply(ies).
2.5 Ensure that sink is clear of tools/debris and is in
normal operating condition.
MJ unit (sold separately)
Note: Do not connect more than 8 solenoids to a single
transformer.