Installation Sheet
Form No. 8878-69  (Revised 3/10/20)    © 2020 Bobrick Washroom Equipment, Inc.    Printed in U.S.A.
2
Spout
Assembly
Base
Gasket
Aerator
and Key
Electronics Box
with  Solenoid
Batteries
Filter
Shank
Mounting Kit
Phillips  Head
Screwdriver
Allen Wrench (3/32")
(Supplied)
Allen Wrench (M3)
(Supplied)
Non-toothed
Wrench
Voltage: Sensor Range: 
Sensor Range:
Operating Water Pressure: 
Operational Water Temperature: 
Flow Control:
6 VDC Series [4 “AA” (Alkaline or Lithium) and/or external power option] 
Self-calibrated, dependent upon sink depth and nish. 
10-125 psi 
33°F to 140°F (1°C to 60°C) 
0.5 GPM / 1.9 LPM Vandal-Resistant Non-Aerated
Overview
Designer Series faucet: the items listed below should already be installed on site.
• Lavatory/sink
• Drain Line
• Hot and cold water supply line or pre-tempered water supply line.
• 
Installer/Servicer should not use pipe dope or teon/thread sealant anywhere on this product, most notably threads 
  and connection points.
• Care shall be taken when installing this product to prevent marring of any exposed or decorative surfaces. 
 Be sure the sink/lavatory/basin is clear from any objects upon making the sensor to electronics connection initiating 
  the self calibration feature. The sink must be clear of any and all objects in order to calibrate appropriately (calibration 
  time approx 30-60 sec).
Designer Series Faucet features multiple spout design in a standard polished chrome nish with one piece heavy duty 
cast brass spout, advanced electronic components and feature sets. Sophisticated automatic user detection and self-
calibration ensures the user does not need to touch the faucet and helps deliver optimum water savings.
Specications
Overview
Prior to Installation
• Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances. 
• Do not convert or modify this product yourself. All warranties will be voided.
• 
Water supply lines must be sized according to building designer in order to provide adequate water supply for each xture.
• Flush all water lines prior to making connections.
Required Tools:
Package Contents