Service Manual

325/328 Excavator
Operation and Maintenance Manual 76
ELECTRICAL SYSTEM (CONT’D)
Removing And Installing The Battery
Open the right side cover.
Figure PM-32
Disconnect the negative (-) cable (Item 1) [Figure PM-32]
first.
Disconnect the positive (+) cable (Item 2) [Figure PM-32].
Remove the bolts (Item 3) [Figure PM-32] and remove
the hold down clamp.
Remove the battery.
Always clean the terminals and the cable ends, even
when installing a new battery.
Install the battery. Install the hold down clamp and tighten
the bolts.
Connect the battery cables. Connect the negative (-)
cable (Item 1) [Figure PM-32] last to prevent sparks.
WARNING
Batteries contain acid which burns eyes and skin on
contact. Wear goggles, protective clothing and rubber
gloves to keep acid off body.
In case of acid contact, wash immediately with water.
In case of eye contact get prompt medical attention
and wash eye with clean, cool water for at least
15 minutes.
If electrolyte is taken internally drink large quantities
of water or milk! DO NOT induce vomiting. Get
prompt medical attention.
W-2065-1296
P19227
1
3
3
2