Service manual

FRONT AUXILIARY CONTROL VALVE (Apitech)
Removal And Installation
(S/N 508411001 – 15215)
(S/N 509711001 & Above)
(S/N 510375001 & Above)
(S/N 510125001 – 16791) (W/Front Aux. Opt.)
(S/N 510250001 – 50691)
(S/N 512811001 & Above) (Ww/Apitech)
Always clean up spilled fuel or oil. Keep heat,
flames, sparks or lighted tobacco away from
fuel and oil. Failure to use care around
combustibles can cause explosion or fire
which can result in injury or death.
W–2103–1285
Disconnect the outlet tubeline which returns to the
hydraulic filter [B].
Disconnect the two auxiliary tubelines [B].
Disconnect the solenoid connector [C].
Remove the two mounting bolts and remove the auxiliary
control valve [D].
Installation: Tighten the mounting bolts to 64–70 ft.–lbs.
(88–95 Nm) torque.
Never work on a machine with the lift arms up
unless the lift arms are secured by an approved
lift arm support device. Failure to use an
approved lift arm support device can allow the
lift arms or attachment to fall and cause injury
or death.
W–2059–0598
A
CD–10962
C
N–10964
D
CD–10965
853, 853H BICS Loader
–2–41– Service Manual
B
CD–10963