Service manual

HYDRAULIC FLUID RESERVOIR
Removal And Installation
Raise the operator cab. (See Page 1–1.)
Disconnect the motor case drain hose from the case drain
filter (Item 1) [A].
Cap and plug the filter and hose. Remove the case drain
filter (Item 1) [A] (if so equipped) and drain the fluid into
a container.
Loosen and disconnect the reservoir outlet hose [B].
Remove the bolt and plate (Item 1) [C] from the mounting
strap.
Installation: Tighten the bolt to 16–20 ft.–lbs. (21–27
Nm) torque.
Remove the hydraulic reservoir from the loader.
A
P–00971
1
C
P–04858
1
–2–38–
853, 853H BICS Loader
Service Manual
B
CD–10954