Service manual

HYDRAULIC FILTER HOUSING
Removal And Installation
Disconnect the tubelines from the inlet of the hydraulic
filter [A].
Disconnect the hose (Item 1) [B] from the outlet of the
filter.
Remove the two mounting bolts and remove the hydraulic
filter and housing [C].
Installation: Tighten the mounting bolts to 25 ft.–lbs. (34
Nm) torque.
Never work on a machine with the lift arms up
unless the lift arms are secured by an approved
lift arm support device. Failure to use an
approved lift arm support device can allow the
lift arms or attachment to fall and cause injury
or death.
W–2059–0598
A
CD–10945
C
CD–10947
853, 853H BICS Loader
–2–35– Service Manual
B
CD–10946
1