DUAL PRESSURE MAIN RELIEF VALVE (S/N
512811001 & Above) W/Select Valve (JEM) (Cont’d)
Checking The High Setting
The tools listed will be needed to do the following
procedure:
MEL10003 – Hydraulic Tester
MEL10006 – Hydraulic Test Kit
Turn the key switch to the OFF position. Before the
engine stops running, turn the key switch all the way to the
left to release the hydraulic pressure at the front auxiliary
quick couplers.
Lift and block the loader. (See Page 1–1.).
Connect the hydraulic tester to the auxiliary quick coupler
[A].
The IN port on the tester connects to the female coupler
on the loader.
The OUT port from the tester connects to the male
coupler on the loader.
The hydraulic tester must be in the fully open
position before you start the engine.
I–2024–0284
W–2017–0286
Put jackstands under the front axles and rear
corners of the frame before running the engine
for service. Failure to use jackstands can allow
the machine to fall or move and cause injury or
death.
Obtain a 3/8 inch (9,5 mm) I.D. hose (Item 1) [B] with a
3000 PSI (20685 kPa) rating or greater.
The hose loop (Item 1) [B] should be approximately of 28
inches (711 mm) in length (including quick couplers).
A small male coupler (Item 2) [B] is needed for one end
of the hose, and a small female coupler (Item 3) [B] is
needed for the other end of the hose.
Use the correct fittings and O–rings to connect the
couplers to the hose.
Drill orifice (Item 1) [C] size to 0.070 inch (1,8 mm). Install
the threaded orifice (Item 1) [C] in the male coupler (Item
2) [C] and install the coupler on the fitting.
A
P–05195
C
P–04757
2
1
–2–24–
853, 853H Loader
Service Manual
B
P–04717
3
1
2