Service manual
INCH. .250 80–90 110–120
LBS. (9,0–10,2) (12,4–13,6)
(Nm)
.3125 180–200 215–240
(20,3–22,6) (24,2–27,1)
.375 25–28 35–40
(34–38) (47–54)
.4375 40–45 60–65
(54–61) (81–88)
.500 65–70 90–100
(88–95) (122–136)
.5625 90–100 125–140
(122–136) (170–190)
.625 125–140 175–190
(170–190) (240–260)
FOOT .750 220–245 300–330
LBS. (300–330) (410–450)
(Nm)
.875 330–360 475–525
(450–490) (645–710)
1.000 475–525 725–800
(645–710) (985–1085)
1.125 650–720 1050–1175
(880–975) (1425–1600)
1.250 900–1000 1475–1625
(1200–1360) (2000–2200)
1.375 1200–1350 2000–2200
(1630–1830) (2720–2980)
1.500 1500–1650 2600–2850
(2040–2240) (3530–3870)
1.625 2000–2800 3450–3800
(2720–2980) (4680–5150)
1.750 2500–2750 4300–4800
(3390–3730) (5830–6500)
1.875 3150–3500 5500–6100
(4270–4750) (7450–8300)
2.000 3800–4200 6500–7200
(5150–5700) (8800–9800)
TORQUE SPECIFICATIONS FOR BOLTS
Torque For General SAE Bolts
The following table shows standard torque specifications for bolts with zinc
phosphate coating. Bolts purchased from Melroe that have zinc phosphate coating
are specified by the letter ‘‘H’’ following the part number.
THREAD
SIZE SAE GRADE 5 SAE GRADE 8
–9–10–
853, 853H Loader
Service Manual