Service manual

FAN GEARBOX/BLOWER HOUSING (Cont’d)
Removal And Installation (Cont’d)
Remove the lock nut and spacer [A].
Installation: Tighten the nut to 45–55 ft.–lbs. (61–75 Nm)
torque.
Use the following procedure to remove the fan from the
shaft:
AVOID INJURY OR DEATH
Wear safety goggles to prevent eye injury
when drilling or grinding.
W–2108–1186
Install the nut (Item 1) [B] on the tapered shaft to protect
the shaft and threads.
Install the puller on the fan as shown [B].
As the center bolt (Item 2) [B] is tightened, periodically
strike the bolt head to loosen the fan from the shaft .
Remove the fan from the tapered shaft [C].
To remove the blower housing mounting plate, remove
the six bolts (Item 1) [D].
A
CD–09952
C
CD–09953
D
CD–09954
1
1
1
853, 853H Loader
–7–15– Service Manual
B
P–03006
2
1