Service manual

FAN GEARBOX/BLOWER HOUSING (Cont’d)
Removal And Installation (Cont’d)
Installation: Use R.T.V. sealant to reseal the blower
housing to the loader frame [A].
Remove the four mounting bolts (Item 1) [B] and spacer
tubes (two outside housing and two inside housing).
NOTE: Remove the two rear mounting bolts first.
Installation: Use sealant on each end of the inside
spacer tubes to prevent the tubes from falling out of the
housing during installation.
Installation: Tighten the mounting bolts to 25–28 ft.–lbs.
(34–38 Nm) torque.
Slide the blower housing forward and remove the fan/fan
gearbox assembly [C].
Remove the blower housing.
The blower housing must be moved away from the loader
frame if the side grills have to be replaced.
To replace the side grill, remove the four mounting screws
(Item 1) [D] from the blower housing.
Install the new grill and replace the screws.
A
P–4877
C
P–4864
D
P–4876
1
1
–7–14–
853, 853H Loader
Service Manual
B
P–4859
1
1