Service manual

HYDROSTATIC PUMP (Cont’d)
Removal And Installation (Cont’d)
Remove the two mounting bolts (Item 1) [A] and nuts
(Item 1) [B].
Installation: Tighten the mounting bolts and nuts to
65–70 ft.–lbs. (88–95 Nm) torque. Make sure the key
(Item 2) [A] is installed.
Remove the mounting bolt (Item 1) [C] at the hydraulic
pump end of the pump.
Remove the hydrostatic pump from the mounting bracket
and drive belt housing.
SEE THE COMPONENT REPAIR MANUAL FOR
HYDROSTATIC PUMPS FOR DISASSEMBLY AND
ASSEMBLY PROCEDURE.
A
P–04933
2
1
1
C
P–04946
1
–3–24–
853, 853H Loader
Service Manual
B
P–04935
1