User's Manual
Intimidator-9
Low Pressure Conversion
To convert the high pressure regulator to low pressure follow the steps below:
1. De-gas marker.
2. Decrease velocity adjustment to relieve spring
pressure.
3. Unscrew the high-pressure regulator housing.
4. Remove piston.
5. Remove orange spring.
6. Remove spring washer.
7. Remove velocity adjuster completely.
8. Turn piston around so that large end is facing
towards pin valve.
9. Install piston, pushing it all the way until it stops.
10. Remove pin valve assembly.
11. Screw regulator housing onto marker.
Note: At this time the low-pressure conversion
is complete. Listed below are key points to
remember.
q Save the removed parts encase you wish to put
the regulator back to original state.
q An external regulator is required when converting
to low pressure.
q Remember to completely remove the velocity
adjuster. Failure to do this will not allow enough
volume for proper recovery.
q Remember to remove pin valve assembly.
Failure to do this will not allow air into required
chambers.
q Ensure large end of piston is facing towards pin
valve.