8. Remove cup seal. Use extreme caution not
to scratch or damage cup seal. It is
recommended to replace the cup seal
every time it is removed. Any small scratch
or fragment on the cup seal will induce an
air leak.
9. Turn body over to gain access to the
bottom of the marker.
10. Remove air barb from middle of sleeve. Do
not loose fiber washer at base of air barb.
11. Remove sleeve retaining allen.
12. At this time you are ready to remove the
sleeve from the body. When removing
rotate the sleeve right and left pulling
towards the rear of the marker. Use
caution to avoid cutting the o-rings. There
are sharp openings that the o-rings must
cross.