User's Manual

BOB LONG GZ INTIMIDATOR PAGE 17
8. Disconnect Grip membrane on backside of
opposite trigger half from 12-point wire
harness.
9. Lift up on LCD white ribbon locks located
each side of ribbon.
10. Remove ribbon from Circuit Board.
11. Remove Circuit Board retaining screw.
12. Disconnect and remove battery.
13. Disconnect 14-point wire harness from
backside of Circuit Board.
14. Remove Circuit Board, and 12-point wire
harness from trigger housing half.
15. Remove 12-point harness from circuit
board.
16. Place Circuit Board and Harness in safe
area to avoid damage.
17. Remove three Phillip screws, remove LCD
screen from trigger housing half. Place in
safe area to avoid damage.
18. Disconnect Air Valve from harness
(green/black wire).
19. Remove Air Valve retaining screw; remove
Air Valve from trigger housing half. Place
in safe area to avoid damage.
20. Remove Trigger Micro switch retaining
screws (2 each).
21. Remove ON/OFF switch retaining screws
(2 each).
22. Push on power indicator light from
backside; pull from front side to remove.
23. Remove 14-point harness from trigger
housing half.