Instructions / Assembly
9
boannstyle.com
Using the EZ Angle Stop Adapter
The Boann R.O. 5-Stage Water Filtration System comes with the EZ Angle Stop Adapter (NSF
Certied). The adapter is a convenient and user-friendly part that faciliates installation. PLEASE
NOTE YOU DO NOT NEED TO TURN OFF THE MAIN WATER SUPPLY LINE when using the EZ
Angle Stop Adapter. DO NOT use Teon tape on this product.
1. To start, turn both Hot and Cold water valves clockwise, turning Off water to both water lines.
Turn the sink faucet On to make sure no cold water is owing. Next, use a wrench to unscrew
the cold water hose from the Cold Water Valve.
2. If the white gasket is not attached to the EZ Angle Stop Adapter, place and push the gasket into
the female threads. After, screw the EZ Angle Stop Adapter onto the 3/8” male threads on the
Cold Water Valve. When resistance is felt, tighten the EZ Angle Stop Adapter one full rotation,
securing the adapter.
Installation Preparation
Turn Valve
Clockwise to
Turn Off
Note!
The Mur-lock® Union-Tee Fitting (V0420426) can be purchased and used
as a supplement tting to connect a 1/4” refrigeration water line to the
water ltration system.