TROUBLESHOOTING - GROUND WATER PUMP SYSTEM
PROBLEM DIAGNOSTIC
TROUBLESHOOTING - CITY DISTRIBUTION SYSTEM
Water temperature is
CHECK water heater is set at 60°C(140°F).
not hot enough.
CHECK the water pressure on the hot and cold
side is identical.
LOOK for air pockets in your plumbing.
LOOK for upside down “U” in all the pipes going to
the shower if so correct it.
Water gets colder
CHECK your water heater. The tank may be
during the shower.
empty, wait 30 min and try again.
Cold water comes
Check the two stainless steel hoses at the
out when the faucet is
back of the shower column, the hot and cold are
set on hot
probably reversed.
Water temperature is
CHECK The main water line pressure is over 5 bars
not hot enough.
or 72.5 PSI.
CHECK water heater temperature is set at
Noise is coming from
60°C/ 140°F
the water line when the
shower panel is on.
Water temperature
he problem is probably coming from your water
decrease to cold
heater. The tank may be empty, wait 30 min and
when it is set on hot.
try again.
8. Water pipes must be flushed and cleaned before connecting the flexible hoses
to the hot/cold water lines to ensure no dirt go inside the shower faucet.
9. After the final tile is installed, you can fix shower panel/column to the stainless
steel steel box without any screws.
Note:
Stainless steel box must be on the same level (flush) with final layer of wall tile to
ensure the shower column fits ont hte smae level as wall tile.