User Manual

RIGOL Chapter 4 Common Modulation Output
User‟s Guide for DG5000
4-16
To Set Hop Frequency
The maximum alternating frequency (“hop” frequency) depends on the current
selected carrier waveform. Press HopFreq to highlight it, input the desire frequency
value using numeric keyboard or knob.
Sine: 1 μHz to 250 MHz
Square: 1 μHz to 120 MHz
Ramp: 1 μHz to 5 MHz
Arbitrary waveform: 1 μHz to 50 MHz
To Set Modulating Polarity
Press Polarity to select the Positive or Negative of the modulating waveform to
control the output frequency.
When internal modulation is selected, if the polarity is positive, logic low of the
modulating waveform amplitude corresponds to carrier frequency output and logic
high corresponds to hop frequency output; if the polarity is negative, the situation is
the opposite.
When external modulation is selected, if the polarity is “positive”, logic low of the input
corresponds to carrier frequency output and logic high corresponds to hop frequency
output; if the polarity is “negative”, the situation is the opposite.