User Manual

RIGOL Chapter 3 Arbitrary Waveform Output
User‟s Guide for DG5000
3-2
To Enable Arbitrary Waveform
Press Arb to open the operation menu of arbitrary waveform.
1. Freq/Period (Sample)
Set the output Frequency/Period of the arbitrary waveform in Normal mode.
Set the sample rate when the generator sample data from external memory in
Play mode.
2. Ampl/HiLevel
Set the output Amplitude/High Level of the arbitrary waveform.
3. Offset/LoLevel
Set the output “Offset/Low Level” of the arbitrary waveform.
4. Phase
Set the Initial Phase” of the arbitrary waveform.
5. Align Phase
Refer to Align Phase.
6. Mode
Select the output mode of the arbitrary waveform to Normal or Play.
7. Select Wform
Select arbitrary waveform stored in internal or external memories.
8. Create New
Users can define waveform with up to 512k points.
9. Edit Wform
Edit the stored arbitrary waveform.
Refer to To Output Sine Waveform to configure the parameters and output. This
chapter will focus on Mode, Sample, “Select Waveform, “Create New” and Edit
Waveform.