Instruction Manual
Chapter 3 Arbitrary Waveform Output RIGOL
DG4000 Series User’s Guide
3-15
Example: Edit Block
The following example introduces how to use “Edit Block” to create an arbitrary
waveform fulfilling the following conditions.
Parameter Value
Cycle Period 12μs
High VLimit 4V
Low VLimit -2V
Interp Linear
X1Y1 2, 4V
X2Y2 4, -2V
Operation Procedures:
1. Press Arb and use to open the 2/2 menu page; then press Create New
Æ Cycle Period, use the numeric keyboard to input “12” and select the unit
“μs” from the pop-up menu.
2. Press High VLimit, use the numeric keyboard to input “4” and select the unit
“V” from the pop-up menu.
3. Press Low VLimit, use the numeric keyboard to input “-2” and select the unit
“V” from the pop-up menu.
4. Press Init #Points, use the numeric keyboard to input “4” and press OK.
Note: at this point, a -2 V level line appears.
5. Press Interp to select “Linear”.
6. Press Edit Block to enter the “Edit Block” interface.
1) Press X1 and use the numeric keyboard to input “2”; then press Y1, use
the numeric keyboard to input “4” and select the unit “V” from the pop-up
menu. Use the same method to set X2 and Y2.
BNC Scientific, a division of Berkeley Nucleonics Corporation
2955 Kerner Blvd, San Rafael CA 94901 USA –www.bncscientific.com
Chat Online or email info@bncscientific.com– Toll Free: 866-276-6188, Fax 707-262-6522