Instruction Manual

RIGOL Chapter 13 Specifications
DG4000 Series Users Guide
13-6
Modulating Frequency
2mHz
to 50KHz
[Mod
/FSK/Trig] Input
Input Range
75mVRMS
to ±2.5Vac+dc
Input Bandwidth
5MH
z
Input Impedance
100Ω
Burst Characteristics
Carrier Waveform
Sine, Square, Ramp, Pulse,
Noise, Arb (except DC)
Carrier Frequency
2
mHz to 100MHz
2
mHz to 100MHz
2
mHz to 60MHz
Burst Count
1
to 1 000 000 or Infinite
Start/Stop Phase
to 360°
Internal Period
2
μs to 500s
Gated Source
External Trigger
Trigger Source
Internal, External or
Manual
Trigger Delay
0ns
to 85s
Sweep Characteristics
Carrier Waveform
Sine, Square, Ramp, Arb (except DC)
Type
Linear, Log or Step
Direction
Up or Down
Start/Stop Frequency
1μHz
to 160MHz
1μHz
to 100MHz
1μHz
to 60MHz
Sweep Time
1ms
to 300s
Hold/Return Time
0ms
to 300s
Trigger Source
Internal, External or Manual
Mark
Falling edge of Sync signal (programmable)
Counter
Specifications
Function
Frequency
, Period, Positive/Negative Pulse Width, Duty Cycle
Frequ
en
cy Resolution
6
digits/second (Gate Time =1s)
Frequ
ency Range
1μHz
to 200MHz
Period
Measurement
Measurement Range
5ns
to 16 days
Voltage Range and Sensitivity (Not modulation signal)
DC
Coupling
DC Offset Range
±1.5VDC
Input Attenuation:
closed
1μHz
to 100MHz
50mVRMS
to
±2.5Vac+dc
BNC Scientific, a division of Berkeley Nucleonics Corporation
2955 Kerner Blvd, San Rafael CA 94901 USA –www.bncscientific.com
Chat Online or email info@bncscientific.com– Toll Free: 866-276-6188, Fax 707-262-6522