Manual
42
Model 835-M Programmer’s 
Manual 
V1.1 2011
:TRIGger 
Subsystem 
Triggers control 
the 
playback 
by telling the 
Model 
835-M
when to play the signal. 
Depending on the trigger 
settings 
for the 
Model 
835-M
, 
the waveform 
playba
c
k
can occur 
once, 
continuously, 
or the 
835-M
may start and stop playing the waveform repeatedly (GATE mode). A 
trigger 
signal comprises 
both 
positive 
and negative 
signal transitions  (states), 
which are 
also called 
high and low 
periods. 
You 
can configure 
the 
835-M
to trigger on 
eit
her 
state of the trigger 
signal. 
It 
is common  
to have multiple 
triggers, also 
referred to 
as 
trig
ger 
occurrences 
or events, 
occur 
when the 
signal 
generator 
requires 
only a 
single 
trigger. In this situation, the 
Model 
835-M
recognizes 
the first 
trigger and 
ignore
s
 the rest. 
When you 
select 
a trigger mode, you may 
lose 
the 
signal 
from the 
RF 
output until you trigger the 
wavefo
rm.
There are four  parts to 
c
o
nfiguring the trigger: 
1. Choosing 
the trigger type which 
controls 
the waveform’s 
tran
s
mission.
x NORMal 
: 
trigger edge 
initiates/stops 
sweeps 
x 
GATE : 
trigger level 
starts/stops 
sweep 
2. Setting the waveform’s 
response 
to triggers: 
— 
CONTinuous : 
reapeatedly 
accepts 
trigger events 
— 
SINGle : uses 
only one trigger 
eve
nt
3. 
Selecting 
the trigger 
source 
which 
determines 
how the 
Model 
835-M
receives 
its trigger signal, 
internally or externally. The 
GATE choice requires 
an external trigger. 
3. Setting the trigger polarity when 
using 
an external source 
Command
  Parameters
Unit
(defa
ult)
Remar
k
TRIGger[:SEQuence]:TYPE  NORMal|GATE|POINt
N/A
  V0.3.10
TRIGger[:SEQuence]:TYPE:GATE  LOW|HIGH HIGH  V0.3.10
TRIGger[:SEQuence]:SOURce  IMMediate|
K
EY|EXT|BUS
IMM
  V0.3.10
TRIGger[:SEQuence]:DELay  <value> 0 
s
  V0.3.10
TRIGge
r[S
E
Qu
ence
]:SLOP
e
  POSitive|NEGative POS  V0.3.10
TRIGge
r[S
E
Qu
ence
]:RETRi
gger
  ON|OFF|IMMediate OFF  V0.3.10
[SOURce]:TRIGger[:SEQuence]:ECOunt <value>
1
  V0.3.10
[SOURce]:TRIGGer[:SEQuence]:OUTPut:POLarity
[
S
OU
Rce]:TRIG
G
er[
:
SEQuence]
:
OU
TPut
:MODE
NOR
M
al|IN
V
erted
NOR
M
al|GAT
E|POINt
NORM
?
V0.3.10
V0.3.10
:TRIGger:TYPE 
TRIGger[:SEQuence]:TYPE 
NORMal 
| GATE  | 
POINT 
TRIGge
r[:SE
Q
uence
]
:TYP
E?
This command  sets 
the trigger type that 
controls 
the waveform’s playback. 
The following list 
describes 
the trigger type 
command 
choices: 
NORMal Upon triggering, the waveform sequence 
plays according 
to 
settlings 
defined by 
 :INITiate:CONTinuous 
(only 
once 
or repeatedly) 
GATE An external trigger 
signal 
repeatedly 
starts 
and 
stops 
the waveform’s 
playback. 
The 
 time duration for 
playback 
depends on the duty period of the trigger 
signal 
and the  
 gate polarity selection. The waveform plays during the inactive state and 
stops during