Manual

37
Model 835-M Programmer’s
Manual
V1.1 2011
[SOURce]:FM Subsystem
(Frequency
Modulation)
Command Parameters Unit
(default)
[SOURce:]FM:DEViation <value>
[SOURce:]FM:SENSitivity <value> 10000
Hz/V
[SOURce:]FM:INT:FREQuency <value>
[SOURce:]FM:SOURce INTernal
|
EXTernal
EXT
[SOURce:]FM:STATe
ON|OFF|1|0 OFF
[SOURce:]FM:COUPling
DC | AC AC
:
FM:DEViation
[SOURce]:FM:SENSitivity
<value>
[SOURce]:FM:
SENSitivity?
This command sets
the
frequency
modulation deviation.
This
setting will be
used
if
:FM:SOURc
e
is
set to
LFGenerator.
The variable <value>
is expressed
in units of
Hert
z.
*RST
10000
:FM:SENSitivity
[SOURce]:FM:SENSitivity
<value>
[SOURce]:FM:
SENSitivity?
This command sets
the frequency modulation deviation per one volt peak amplitude signal
input.
This
setting will be
used
if
:FM:SOURce is
set to EXTernal. The
variable <value>
is expressed
in units of Hertz per
Volt.
*RST
10000
:
FM:IN
T:FR
E
Q
uency
[SOURce]:FM:INT:FREQuency
<value>
[SOURce]:FM:INT:FREQuency?
This command sets
the
frequency
modulation rate in Hz.
This
setting will be
used
if :FM:SOURce
is
set to INTernal.
The variable <value>
is expressed
in
Hert
z.
*RST
:FM:SOURce
[SOURce]:FM:SOURce EXTernal |
INTernal
[SOURce]:FM:SOURce?
This command selects
the FM modulation
signal source.
If
INTernal is selected,
an
inter
nal
modulation
source is
applied. If
EXTernal is selected,
the
device’s
)
M
input (at the rear panel) is activated.
*RST
EXT
:FM:STATe
[SOURce]:FM:STATe
ON|
O
FF|1|
0
[
S
OU
Rce]
:FM:STA
Te?
This command
turns the
frequency
modulation on or
off.
*RST
OFF
:FM::COUPling