Instruction Manual

A-1
Appendix A - 575 Specifications
INTERNAL RATE GENERATOR
RATE (T
0
period) 0.0002 Hz to 20.000 MHz
RESOLUTION 10ns
ACCURACY Same as timebase
JITTER < 50 ps
SETTLING 1 period
BURST MODE 1 to 9,999,999 pulses
TIMEBASE 100 MHz, low jitter PLL
OSCILLATOR 50 MHz, 25ppm
SYSTEM OUTPUT MODES Single pulse, burst, duty cycle, external
gate/trigger
PULSE CONTROL MODES Internal rate generator, external
trigger/gate
PROGRAMMABLE TIMING GENERATOR
CHANNEL OUTPUT MODES Single shot, burst, duty cycle, normal
CONTROL MODES Internally triggered, externally triggered
and external gate. Each channel may be
independently set to any of the modes.
OUTPUT MULTIPLEXER Timing of any/all channels may be
multiplexed to any/all outputs.
WAIT FUNCTION 0 to 9,999,999 pulses
TIMEBASE Same as internal rate generator
WIDTHS
RANGE 10 ns-999.99999999975 s
ACCURACY 1 ns + 0.0001 x width
RESOLUTION 250 ps
DELAYS
RANGE 0-999.99999999975 s
ACCURACY 1 ns + 0.0001 x delay
RESOLUTION 250 ps
PULSE INHIBIT DELAY < 120 ns typical
OUTPUT INHIBIT DELAY < 50 ns typical
SYSTEM EXTERNAL TRIGGER/GATE INPUT(S)
TRIGGER INPUT
FUNCTION Generate individual pulses, start a burst
or continuous stream
RATE DC to 1/ (200 ns + longest active pulse).
Maximum of 5 MHz