Technical information

If the high-voltage rescue separation point behind the trim panel cannot be accessed, the high-voltage system is
switched off at the large high-voltage connector of the high-voltage battery (installation position below the luggage
compartment floor cover).
.
The high-voltage system is to be switched off by removing the small pole connector (HV interlock) (see chapter 3.1.2
point 9).
.
3.1.2 Determine voltage free status
A switched off high-voltage system can be identified via the message "High-voltage system deactivated" in the instrument
cluster.
Note: The display requires the 12 V battery to be connected and a terminal change (stop and start vehicle via start/stop
button) to be carried out.
If the de-energised state cannot be identified by means of the instrument cluster (no message), the state can be identified
by a qualified electrical specialist with personal protective equipment via the following measurements.
.
Operations:
1. Switch off vehicle. Put vehicle in passive state via START-STOP button.
2. Remove vehicle key
3. Open tailgate and lift luggage compartment floor cover (1).
Page