Technical information
In the next step, measurements can be taken from each of the contacts to the housing of the electrical machine
electronics. The housings of all high-voltage components are connected via GND by means of potential compensation
lines (aluminium drive module). If a high-voltage potential is present at the housing and/or at GND due to damage, it can
be measured with this procedure.
If no voltage is measured at any time, one can assume that the system is no source of danger.
.
9. Installing the high-voltage connector
In order to rule out further improper treatment, install and lock the high-voltage connector again. The smaller connector
(HV switch-off) must not be installed again.
.
10. Close engine compartment with service cap
.
3.2 Vehicle on fire
In general, all statutory requirements relating to a conventional vehicle on fire are to be observed.
No explosion will occur in the event of a reaction of the lithium ion high-voltage battery triggered by the fire. A quick