Technical information
A switched off high-voltage system can be identified via the Check Control message "High-voltage system deactivated" in
the instrument cluster.
Note: The display requires the 12 V battery to be connected and a terminal change (stop and start vehicle via start/stop
button) to be carried out.
If the de-energised state cannot be identified by means of the instrument cluster, the state can be identified by a qualified
electrical specialists with personal protective equipment via the following measurements.
Operations:
1. Switch off vehicle. Put vehicle in passive state via START-STOP button.
2. Remove vehicle key
3. Open tailgate.
4. Disconnect 12 V battery.
5. Remove luggage compartment floor cover.
6. Remove service cap. Release 8 screws (arrows) and take out the engine compartment cover.