Product Manual

TRAILSAFE+ OPERATIONAL USE WITH SWAYCONTROL
The LED on the TrailSafe+ displays different indicators if used with BMPRO’s
SwayControl.
NOTE: If you are not using the TrailSafe+ with BMPRO’s SwayControl, refer to the
Operational Use section of this manual.
Battery flat
Always
on
The battery is flat.
Warning: this state will
override other LED indicators.
Refer to the Battery Flat
section for more information.
Charge or replace the house
battery.
Normal
operation,
battery
sufficient
Sway event
active
Standby
mode
The TrailSafe is in standby as no brake activity has been detected
for 1 minute, and the SwayControl is in “sleep” mode
Battery
insufficient
The house battery may have
insufficient capacity for
15 minutes of emergency
braking operation.
Check the battery to ensure
at least 10Ah of house battery
capacity is available.
SwayControl
not detected
The SwayControl is not
detected by the TrailSafe+.
Check if the SwayControl is
connected.
No power
No power to SwayControl
after a “wake-up” signal from
the brake controller.
Check the quality of power,
ground and brake controller
wire connections. Check for any
blown fuses on the tow vehicle
and trailer.
Battery
overvoltage/
undervoltage
There is a house battery
overvoltage(> 20V) or
undervoltage (< 3V) on the
SwayControl.
Check the power source voltage.
The required voltage is 12-15V.
CONDITIONSTATUS SOLUTIONSTATE
10s
18