Product Manual

INSTALLATION INSTRUCTIONS
PERSONNEL
Installation is to be carried out only by suitably qualified personnel.
EARTHING
As the BP35-11 is positive sensing for current monitoring, this allows for chassis
earthing of both the battery and the negative of DC 12 V appliances.
Note: All DC 12 V positive cables must be wired to outputs 1-14 or the 40A battery
output connection.
Loads greater than 15A
For DC 12V appliances that may draw greater than 15A, such as inverters, both
positive and negative must be wired direct to the new Battery negative on the BC300
(See Figure 2) to ensure that the current is seen by the BP35-II and the correct
information displayed, particular State of Charge & Time Remaining.
Refer to our website for more information on this product
https://teambmpro.com/products/bc300-commlink-external-shunt/
13