Product Manual
10
BATTERY MONITORING SPECIFICATIONS
Voltage Range 8V to 16V
Voltage Resolution < 20 mV
Current Resolution < 200 mA
Current Range 240 A, continuous
Overload Protection
(100ms without damage)
±800 A
Temperature Range (Battery Terminal) -20°C to 70°C
Temperature Resolution 3°C
Capacity Range 7 to 800 Ah
GENERAL SPECIFICATIONS
BC300
External Shunt
CommLink
Input Voltage 8 V to 16 V
Quiescent Current Drain (average) < 10 mA < 20mA
Operating Temperature -20°C to70 °C
Humidity Operating ≤ 85% RH Non-condensing
Humidity Non-operating ≤ 95% RH Non-condensing
Dimensions (Approx.) 140 x 65 x 18.6 mm 92 x 52 x 25 mm
Weight (Approx.) 1kg 150g
IP Rating IP 54 IP 30
SPECIFICATIONS