Specifications

Approval sheet
Page 10 of 12 ASC_RFECA3216060A1T_V09 Aug. 2018
Bending test
JIS C 0051- 7.4.1
The middle part of substrate shall be
pressurized by means of the pressurizing rod
at a rate of about 1 mm/s per second until the
deflection becomes 1mm/s and then pressure
shall be maintained for 51 sec.
Measurement to be made after keeping at
room temperature for 242 hours
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
Temperature cycle
JIS C 0025
1. 303 minutes at -40C3C,
2. 10~15 minutes at room temperature,
3. 303 minutes at +85C3C,
4. 10~15 minutes at room temperature,
Total 100 continuous cycles
Measurement to be made after keeping at
room temperature for 242 hrs
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
High temperature
JIS C 0021
*Temperature85C2C
*Test duration1000+24/-0 hours
Measurement to be made after keeping at
room temperature for 242 hrs
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
Humidity
(steady conditions)
JIS C 0022
*Humidity90% to 95% R.H.
*Temperature402C
*Time1000+24/-0 hrs.
Measurement to be made after keeping
at room temperature for 242 hrs
500hrs measuring the first data then
1000hrs data
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
Low temperature
JIS C 0020
*Temperature-40C2C
*Test duration1000+24/-0 hours
Measurement to be made after keeping at
room temperature for 242 hrs
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.