Installation Guide
Dimensions in millimeters (inch equivalents as noted) © 2015 Blum, Inc.
68
Hinges
TIP-ON in-line and wing adapter plate specifications
In-line adapter plate
Catch plate (screw-on)
Catch plate (self-adhesive)
Wing adapter plate
Pre-boring Ø2.5 mm counter-
sunk pilot holes required
OL = Door overlay
Cleaning of the door
surface is recommended
NOTE: Factory setting of door gap is 2 mm
NOTE: Minimum gap of
3 mm with a screw-on catch
plate and 2.5 mm with a self-adhesive catch plate
TIP-ON boring specifications
Standard TIP-ON set
Catch plate (screw-on)
Pre-boring Ø2.5 mm counter-
sunk pilot holes required
OL = Door overlay
Catch plate (self-adhesive)
Cleaning of the door
surface is recommended
Large TIP-ON set
NOTE:
Minimum gap of
3 mm with a screw-on catch
plate and 2.5 mm with a self-adhesive catch plate
2.5 (3) min.
50 min.
2.5 (3) min.
76 min.
General specifications
Tool-free door gap adjustment
The adjustment feature (+4/-1 mm) has been incorporated into the TIP-ON unit so even when TIP-ON is inserted into the cabinet, it
has an integrated gap adjustment. To adjust gap, turn the ejector pin. The click-stop positions allow you to easily find the right setting.
TIP-ON
for doors
Ø10
7.5
OL
1
13
7.5
OL
Installation position
Optimal opening support is
achieved if the TIP-ON unit is
attached exactly where the
handle would be.
The fixing position can deviate
±12" in height and up to a
quarter of the cabinet width in
terms of width.
1.5 min.
1.5 min.
9
OL
9
OL