Drawer removal
1
Squeeze release levers on locking devices
2
Pull drawer straight out and up
1
2
Attach locking devices
1
Position locking device in front corner of the drawer
2
Pre-bore locking device mounting screw holes with Ø2.5 piloting bit
3
Attach with two 606N or 606P screws
4
Repeat on the other side
NOTE: A minimum of 16 (5/8") sub-front thickness is required for mounting the narrow drawer locking device
95 (3-3/4") to 124 (4-7/8")
16 (5/8") min.
Drawer back preparation
Rear view
7 (9/32")
11 (7/16")
Ø6 x 10
Bore for hook
35 (1-3/8") Minimum rear notch
13 (1/2")