Brochure

© 2015 Blum, Inc. Subject to technical modifications without notice
73
Hinges
Cycle test
Without load
100,000 opening
and closing for all
COMPACT
Positive test result
With load
11 lb extra weight is
applied for 100,000
opening and closing cycles
Positive test result
Load test
Static load
67 lb applied ten times for
five seconds, each at 45°
opening angle
Positive test result
Dynamic load
44 lb extra weight applied
for fifty opening and
closing cycles
Positive test result
Over push test
Without load
COMPACT hinges – Increasing forces up to 11 lb applied
for a total of forty times for five seconds each
Positive test result
Conditions for tests
Blum, Inc. does a great deal of testing to ensure that the quality of our hardware is consistent with the usual high
standards that our customers have come to expect from Blum. For this reason we have rigorous testing procedures which
are carried out from the development stage through production. Blum’s internal testing standards are based on practical
applications of our products and are more stringent than what is required by ANSI/BHMA.
COMPACT testing standards
kg
kg
Cycle test
Specifications
Door size – 23-5/8" height, 23-5/8" width, 3/4" thickness
Door weight –14.3 lb for cycle tests
Door weight – 18.5 lb for load and over push tests
Boring distance – 3 mm
Distance between
hinges
16-15/16"
Hinge and mounting
plate attachment
Hinges are mounted to test blocks and attached to test door and stand with clamps
Test blocks for door: Particle board
Test blocks for mounting plate: Particle board
NOTE: All Blum hinges meet or exceed ANSI/BHMA A156.9-2001 grade 2 requirements. All concealed hinges are designed for indoor use.